Choose post hardware from the real mounting condition. A base fixed on top of a surface, a side-mounted fascia plate, an adjustable interface and a core-mounted post create different geometry, installation access and site responsibilities. Caps and covers finish visible openings but do not replace structural fixing components. This category routes those tasks separately.
Discuss mounting hardware on WhatsApp
Current hardware routes
Use where posts are fixed on top of a prepared supporting surface. Show the finished build-up, base position, anchor responsibility and cover requirement.
Use for side-mounted posts. Provide the structural face, post offset, access behind the fixing, edge geometry and alignment target.
Use when a defined adjustment is required for installation. State the adjustment direction, required range and final locking/cover condition.
Use only when the project has a defined demand for a more substantial base detail. The title is not a load rating; submit design loads and substrate information for review.
Bevestigingssystemen voor de kern
Use for posts installed into prepared openings. Coordinate hole geometry, embedment, drainage/waterproofing, fixing material and installation sequence.
Use for visible tube ends and post tops. Match the receiving profile, exposed edge, cap form, finish and intended retention method.
Representative fixing and finishing parts
Structural fixing is not the same as visible finishing
Component — Primary job — Must be matched to
Base plate or mounting body — Transfers the post connection to a defined support. — Post profile, design action, substrate, edge geometry, anchors and installation access.
Cover or trim — Conceals or finishes a visible interface. — Base footprint, post shape, finished floor level, removability and finish.
Post or end cap — Finishes an open tube or post top. — Outside/inside receiving profile, edge condition, retention method and visible form.
Do not treat a cover as the structural base or infer that fasteners shown beside a product are suitable for the project substrate. The quotation should identify what is included, while the project designer or engineer defines the required installed capacity and anchor design.
Choose the mounting route from site constraints
• Surface mount: record the structural surface beneath finishes, edge distance, level tolerance, water path and whether the base remains accessible.
• Fascia mount: record the side structure, bolt access, post offset, finish build-up and how repeated posts will be aligned.
• Adjustable base: state exactly what must move – height, angle, rotation or plumb – and how the final position is locked and covered.
• Core mount: coordinate the prepared opening, post insertion, temporary support, fixing/grouting sequence, drainage and waterproofing.
• More substantial base detail: provide design actions and substrate information. “Heavy duty” is a product route, not evidence of a universal capacity.
Inquiry package and quotation checks
A photo of the mounting area plus a section sketch is often enough to start. Add the post profile, base elevation, substrate description, available edge distance, access, exposure, finish and estimated quantity.
Ask the proposal to state:
• mounting body or plate geometry and its post interface;
• cover, cap or trim pieces included;
• loose fasteners or anchors included, proposed or excluded;
• material grade and finish proposed for each visible part;
• adjustment direction and locking detail where relevant;
• site drilling, grouting, welding, waterproofing and finishing responsibilities;
• drawings, design actions and substrate data still needed before production.
Choose between level, raked, and raked-to-level mesh panel geometry by railing run, pattern orientation, interfaces, and project drawings.
Specify handrail sleeves and splice locks by the actual tube interior, required retention and installation access so the connector can fit and be secured.
Zorg ervoor dat verbindingspunten worden voorzien van steunen, overgangen en toegangsmogelijkheden voor montage, zodat de breekpunten voor het transport ook fungeren als gedocumenteerde verbindingen in de geïnstalleerde leuning.
Connect the usable rail path with joint function, supports, movement and transport modules before issuing a continuous handrail specification.
Send coordinated run drawings, substrate details, finish references and scope requirements so surface-mount handrail quotes can be compared meaningfully.
Leg de bestaande ondergrond, de toestand van de randen, de afwerkingen, verborgen leidingen en installaties, de toegankelijkheid, de geometrie en de omvang van de reparatiewerkzaamheden vast voordat met de fabricage voor de aanpassing wordt begonnen.


Foshan ESANG Metal Products onderhoudt met trots CE-certificering (Verificatienummer TD32772401) onder de Richtlijn bouwproducten (Verordening nr. 305/2011), waarmee we onze toewijding aan de hoogste Europese veiligheids- en kwaliteitsnormen bevestigen.
Gecertificeerd Assortiment:
Ons uitgebreide assortiment railingbeslag - inclusief glasklemmen, spanners, beugels, muurbevestigingen, basischoenen, leuningbeslag, kabelbeslag en staanderonderdelen - voldoet aan de volgende eisen EN1906:2012 normen, zodat de structurele integriteit en betrouwbaarheid van de prestaties in alle installaties gewaarborgd zijn.
Wat dit betekent voor je project:
✓ Volledige naleving van regelgeving voor Europese en internationale markten
✓ Onafhankelijk geverifieerde veiligheids- en duurzaamheidsprestaties
✓ Documentatie-ondersteuning voor architecturale specificaties
Gemoedsrust dankzij kwaliteitsgarantie van derden
Certificering geldig tot 2027 | Testrapport: CE-FE24122001-CY

